HAINEWS  Product News from Higgins Analytical

January 1998

In This Issue:
        New Product News
        Targa C18 Customer Feedback


NEW PRODUCT       Haiflticon.jpg (2008 bytes)            
           
HAIFILTER "...an ideal solution for high performance, in-line filtration needs ."
HAIFILTER is now available in two formats. The leak-free, finger-tight, and efficient performance are qualities of the HAIFILTER that have made it a popular product, replacing the competition's awkward and leaky alternatives in many labs worldwide. (Higgins Analytical HPLC products are currently being used in 22 countries!). The direct-connect feature in the original design makes the HAIFILTER FM ideal for protecting HPLC columns. In addition, many of our customers have requested a symmetrical version for their filtration needs in other configurations. We are now shipping the new HAIFILTER FF that has standard female threads on both ends, giving you unequaled flexibility to address your filtration needs.

HAIFILTER Special Features

Leak-free performance
Low dead volume
No tools required
Two convenient designs
Inert PEEK construction
Stainless steel, titanium or PEEK frits



HAIFILTER Ordering Information

HAIFILTER FM (Female/Male) Starter Kits:
HF-FKIT     HAIFILTER (Standard)
HF-WKIT    HAIFILTER (for Waters HPLC columns)
HF-RKIT     HAIFILTER (for Rheodyne injection valves - Specify model when ordering)

Note: HAIFILTER FM Starter Kits include a package of 10 filters (HF-SFILT), a 10cm piece of PEEK tubing, and a PEEK bushing and ferrule.

HAIFILTER FF (Female/Female) Starter Kit
FF-FKIT     HAIFILTER FF

Note: The HAIFILTER FF Starter Kit includes a package of 10 filters (HF-SFILT), two 10cm pieces of PEEK tubing, and two PEEK bushings and ferrules.

Replacement Filters:
All replacement kits contain 10 filters per package

HF-SFILT     Stainless steel HAIFILTER replacements
HF-TFILT     Titanium HAIFILTER replacements
HF-PFILT     PEEK HAIFILTER replacements

Customer Feedback

Targa C18 "...a significant improvement in column technology."
We introduced Targa C18 5µm at the HPLC `97 show in Birmingham last summer and immediately we began receiving outstanding reviews. Chromatographers with tough-to-chromatograph basic compounds have shown that Targa C18 outperforms Waters Symmetry, YMC Basic, Hypersil BDS, and Inertsil ODS3. A pyridine/phenol test in extremely unforgiving conditions, unbuffered 20% acetonitrile in water, produces symmetrical peaks with no tailing, as shown below.

patelpyicon.jpg (1813 bytes)


Data provided by Kamlesh Patel from the University of North Carolina's Department of Chemistry demonstrated that Targa C18 has an extremely well-protected silanol surface. Acetonitrile/water 1%/min gradients with as little as 0.05% acetic acid, gave a very nice peptide map on a short 5cm x 1mm Targa C18 column.

patelcyicon.jpg (1876 bytes)


The behavior of basic peptides on Targa C18 is illustrated in the figures below. Good peak shape is achieved, even when using acetic acid buffer, which is not the case with most HPLC columns

!pepstdsicon.jpg (2044 bytes)                                           Pepstd1icon.jpg (2023 bytes)


Patel also suggests that in many cases buffer in the mobile phase may be eliminated completely, making Targa C18 columns ideal for LC/MS applications.


Home | Go to Top | Targa Products
© 1998 Higgins Analytical, Inc (8July98)